Type 6000 - BMC (Bulk Molding Compound) (1)
Arc & Track Resistant
UL Recognized (2)
|
| PROPERTIES |
TEST METHOD ASTM |
GLASS CONTENT
15%
20% |
| Flexural Strength, psi |
D790 |
12 - 14,000 | 14 - 16,000 |
| Tensile Strength, psi |
D638 |
4 - 5,000 | 5 - 6,000 |
| Compressive Strength, psi |
D695 |
15 - 18,000 | 18 - 20,000 |
| Water Absorbtion, % 24 Hours @ 23° C |
D570 |
0.2 | 0.2 |
| Impact Strength, Notched izod ft/lb./in |
D256 |
4 - 5.0 | 5 - 6.0 |
| Heat Distortion, °F @ 264, psi |
D648 |
400+ | 400+ |
| Specific Gravity |
D792 |
1.8 | 1.8 |
| Shrinkage - Mils/in. |
|
1.3* | 1.3* |
| Flammability |
UL94 |
VO/5V | VO/5V |
| Dielectric Strength, v/mil, Perp, ST, in oil |
D149 |
375 - 400 | 350 - 375 |
| Arc Resistance, Sec. |
D495 |
180+ | 180+ |
| Track Resistance min/1in., inclined plane |
D2303 |
600+ | 600+ |
(1) Qualified MAI60, MIL-M-14M
(2) UL File No. - E43298
* Also Available @ 0-0.5 Mil/in (non pigmentable)
|
Physical and electrical properties described above were determined with
recognized test methods. They should be considered representative only. ZEHRCO-GIANCOLA COMPOSITES, INC. assumes
no liability for performance of this product in user's application, nor for infringement
of any patent. No warranty is expressed or implied, including
without any limitation warranty of merchantability or fitness for a particular purpose.
Under no circumstances will ZEHRCO-GIANCOLA COMPOSITES, INC. be liable for incidental or
consequent loss or damage.
|